clinker cooler design with parts

CLINKER COOLING TECHNOLOGY - Mechanical ...

Improved grate design to distribute clinker more uniformly across the cooler - grate area. 4. Improved mechanical components, particularly grate plates, to give less wear and tear resulting in better service.

FLSmidth® Cross-Bar® Cooler The latest standard in clinker ...

cooler housing Horizontal design with optimised transport method – Low civil costs, low wear rates The cooler’s new drive mechanism is designed to obtain optimal transport efficiency. Each lane of movable frames in the cooler is ...

Clinker Grate Cooler for Cement Plant

The grate coolers can be divided into two main types: Traveling grate cooler, Reciprocating grate cooler Working principle of Clinker Grate Cooler: The high-temperature clinker is discharged from the kiln inlet to boring machine, and is distributed along the entire length of boring machine under the push-pull plate, formed a bed of a certain thickness.

ETA Cooler - Claudius Peters

In this design, core parts such as lanes, sealings, rollers and hydraulic systems are delivered by Claudius Peters as loose parts to site. Although a semi-modular design involves lower capital expenditure, actual work on site is longer when compared with the modular ETA Cooler.

Latest Developments in High Efficency Clinker Cooling

ETA Cooler Grate Cooler Self-protected design with pebbles and high clinker layer Burnt and broken grate plates possible, due to direct hot clinker contact Hardfacing Lane filling with pebbles Photo courtesy of client 17 ETA has ...

Cement Kilns: Rotary Coolers

The rest of the cooler, in which the clinker is usually below 800°C, is provided with steel liner plates (mainly to protect the structural shell from abrasion), and lifters. In the hotter part, the lifters are in the form of buckets made from cast high temperature steel. In the cooler parts…

PERFORMANCE EVALUATION OF A GRATE COOLER IN ...

of various additives. Also, cooler helps to recuperate heat from clinker and also to crush the clinker to the acceptable feed size for cement mill. This is presented on the Figure 2.1. Fig 2.1: The Inner View of a Grate Cooler with

FLSmidth Cross-Bar Cooler

Five fundamental design features 3 Since FLSmidth introduced the world’s first cross-bar cooler in 1997, we’ve sold hundreds of cross-bar coolers around the world. The FLSmidth Cross-Bar Cooler …

Cement Wet Process & Cement Dry Process - Cement ...

2020/11/30 · After cooled down in the grate cooler, they will be sent into the grinding mill for the last processing. In the last stage, clinker will be ground into qualified fineness in grinding mills. During this process, we usually add some gypsum and other materials into clinker to give the final cement product different properties and usages.

Cement Equipment In Cement Plant | AGICO Cement Plant ...

2020/11/06 · As a cement equipment supplier and cement plant manufacturer, AGICO offers quality cement kiln, cement vertical mill. cement ball mill, hammer crusher, etc. Besides, we provide cement production line, stone crushing

Clinker cooler with Coanda Wing® technology - IKN

2018/09/19 · The main features of the clinker cooler with Coanda Wing® grate plates are: Excellent clinker distribution resulting in uniform, efficient cooling of the clinker across the full width of the cooler. Low construction height and compact design. High thermal recuperation efficiency.

Cross-Bar® Cooler for efficient clinker cooling | FLSmidth

With few wear parts, the FLSmidth Cross-Bar Cooler is easy to maintain and economical to run. The bar and U-profile are easily accessible, and a protective layer of clinker ensures a long lifetime for the air distribution plates. All this means fast and predictable maintenance – for lower operating costs.

Clinker Cooler Plate, Blow Bar And Crusher Hammer For ...

Hot clinker falls from Kiln on the cooler plate. Size of the Clinker ranges from 50 mm to 250 mm. Cooler plate gets cooled and travelled to Clinker Breaker. Operation subjected to impact / abrasion and high temperature oxidation.

Process Coolers for Cement Clinker | Ammermann Pty Ltd

The main features of the clinker cooler with Coanda Wing® grate plates are: Excellent clinker distribution resulting in uniform, efficient cooling of the clinker across the full width of the cooler. Low construction height and compact design. High thermal recuperation efficiency.

Cool Down Feinkonzept 08 Einzel - Home - IKN

The Pendulum Cooler® is the only cement clinker cooler designed without any active or lubricated components within the cooler housing. Together with the wear resistant and maintenance free spring steel straps of the LPS®, this design ensures that access to the inside of the cooler is only required for inspection during the annual shutdown.

Clinker_cooler | Machines | Manufactured Goods

1 Rolls 2 Longitudinal girders 3 Cross girders 4 Attaching parts 5 Air cooling 6 Drive unit 7 Platform 8 Dismounting device Page 42 SilzR 10 Jul 2002 S:\Dept\A600All\Auftrag\Kujafa\Training Roller crusher Page 43 SilzR 10 Jul 2002 S:\Dept\A600All\Auftrag\Kujafa\Training_KUJAFA\Training onsite\3.2_Mech. maintenance_engineers\Trainingsunterlagen_Gruttmann\3.2.08_Clinker_cooler\Kujafacooler.ppt

Cement Kilns: Grate Coolers

All these are modifications of the basic reciprocating cooler design. In addition, the crossbar cooler has become available since 2000. This has a fixed grate with zero fall-through, the clinker being moved by reciprocating cross

Clinkerization - Cement Plant Optimization

2020/05/16 · Cooler Clinker cooler serves two main objective of cooling clinker from temperature of about 1350 0C to the temperature (65-150 0C) where it can be handled by conveyors like pan conveyors, chain, Elevators etc. and heat recovery

Reduce stoppages with the ABC™ Cooler Inlet | FLSmidth

Minimised maintenance requirements on cooler parts The ABC™ Cooler Inlet gives you all the advantages of a stationary inlet section, including a long service life and good cooling-air distribution. But it also includes a unique patented in grate air blasting system, which means more uniform clinker distribution – and no snowmen.

Clinker cooler - Endress+Hauser Portal

Clinker cooler Level control with capacitance probe and monitoring electronic High temperature probe Separate located electronic unit Discharge bins of clinker fines Nivotester FTC625 Features • Process temperatures up to 400 C